Instruments
Bring the kit that is already on your truck
Twelve instrument integrations are available over Bluetooth in the installed app. Mix supported brands on one call and bring their readings together on one screen. Check the model and measurement limits below.
By brand
-
Sauermann
HVAC probes and DBM620
- Models
- Si-PM3 · Si-TT3 · Si-HH3 · Si-VV3 · Si-VH3 · DBM620
- Covers
- Pressure probes, Temperature clamps and air probes, Humidity probes, Air velocity probes
- Before use
- Model-specific differential pressure, temperature, humidity and air velocity. DBM620 provides its measured pressure and air-sensor channels; calculated hood airflow is not included. Physical reading comparisons remain pending.
-
Sauermann
Legacy refrigeration probes
- Models
- Si-RM3 · Si-RV3 · Si-RP4 legacy
- Covers
- Pressure probes, Temperature clamps and air probes, Vacuum gauges
- Before use
- Capabilities and units are read before streaming. Model identity distinguishes vacuum from pressure and selects the RP4 generation. Physical reading comparisons remain pending.
-
Sauermann
Si-RS1 scale
- Models
- Si-RS1
- Covers
- Refrigerant scales
- Before use
- Signed scale reports in kg, lb and combined pounds/ounces. Physical reading comparisons remain pending.
-
Sauermann
Wireless probes
- Models
- Si-RT7 · Si-TH4 · Si-RV4 · Si-RP4 BCP
- Covers
- Temperature clamps and air probes, Humidity probes, Vacuum gauges, Pressure probes
- Before use
- OEM acquisition checks CRC and record status, with separate internal/external temperature, relative humidity and absolute vacuum channels where supplied by the model. Physical reading comparisons remain pending.
-
AccuTools
BluVac+
- Models
- Professional · Pro · LTE · Micro
- Covers
- Vacuum gauges, Temperature clamps and air probes
- Before use
- Direct vacuum acquisition across four BLE generations; Pro and original Professional also provide ambient temperature. Oil lockout and values outside the numeric range are withheld. Pro packets have been captured; physical vacuum display comparisons remain pending.
-
Parker
SensoNODE Blue
- Models
- Pressure · Temperature · Humidity · Service Junior CONNECT · 4–20mA adapter
- Covers
- Pressure probes, Temperature clamps and air probes, Humidity probes, Electrical meters
- Before use
- Live BLE descriptors establish numeric format, scale and units. Gauge and absolute pressure remain distinct. The loop adapter reports current; converting it to an attached transducer quantity requires that transducer configuration. SensoNEXT is a separate generation.
-
Yellow Jacket
Wireless scale
- Models
- YJScale
- Covers
- Refrigerant scales
- Before use
- Separate scale connection with explicit unit initialization, signed tared weight and battery. Physical reading comparisons remain pending.
-
CPS
CCW scale
- Models
- CCW
- Covers
- Refrigerant scales
- Before use
- Signed gram readings, including refrigerant removed after tare. Physical reading comparisons remain pending.
-
CPS
VOLT-100
- Models
- VOLT-100
- Covers
- Electrical meters
- Before use
- Model-specific startup and main-display electrical quantities. Hold, relative and ambiguous auxiliary modes are withheld. Physical reading comparisons remain pending.
-
Sauermann
Digital manifolds
- Models
- Si-RM350 · Si-RM450
- Covers
- Digital manifolds, Pressure probes, Temperature clamps and air probes
- Before use
- OEM measurement acquisition provides two gauge-pressure ports and named temperature inputs. Fault status and reported units are checked independently. Physical reading comparisons remain pending.
-
Fieldpiece
Job Link
- Models
- JL3PR · JL3PC / JL3LC · JL3RH · JL3MN · SM380V / SM480V · SMAN380 / SMAN480 · SM382V / SM482V · MG44 · SC480 / SC680 · SRS3 / SR47 / SR47EC
- Covers
- Digital manifolds, Pressure probes, Temperature clamps and air probes, Humidity probes, Vacuum gauges, Electrical meters, Refrigerant scales
- Before use
- Channels depend on instrument. JL3PC temperature has a physical reading comparison. SC680 electrical modes include separate AC/DC, inrush, power, resistance, capacitance and temperature quantities from the OEM protocol. Loaded electrical, scale and manifold readings still need field validation; invalid and overloaded readings are withheld.
-
Testo
Smart Probes and manifolds
- Models
- 115i · 510i · 549i · 550 / 557 · 550i · 550s / 557s / 558s / 570s · 552 / 552i · 605i · 805i · 905i / 915i · 405i / 410i · 420 · 560i · 110 / 925 / 922 · 625 · 512-1 / 512-2 · 416 / 417 / 425
- Covers
- Digital manifolds, Pressure probes, Temperature clamps and air probes, Humidity probes, Airflow instruments, Air velocity probes, Vacuum gauges, Refrigerant scales
- Before use
- 115i and 549i have physical reading comparisons. Named vacuum, airspeed, temperature, humidity and scale properties are decoded by quantity. The 552 and compact instruments report SI values independently of display units; modern manifold channels use reported metadata. Other channels depend on model and firmware. Classic 550/557 battery percentage is not established.
-
Testo
770-3 clamp meter
- Models
- 770-3 / T770 / T773
- Covers
- Electrical meters, Temperature clamps and air probes
- Before use
- Separate AC/DC values, resistance, capacitance, temperature and named power quantities are implemented from application protocol evidence. Unsupported modes are withheld. Physical reading comparisons remain pending.
-
Parker Sporlan
SMART Pro / R
- Models
- SMART Pro / R
- Covers
- Pressure probes, Temperature clamps and air probes
- Before use
- Supported temperature and pressure frames are decoded. Unresolved pressure encodings are withheld; battery percentage is not established.
-
Yellow Jacket
TITAN / P51 / YJACK
- Models
- TITAN · P51 · YJACK pressure, temperature and humidity probes · YJMano · YJFLOW
- Covers
- Digital manifolds, Pressure probes, Temperature clamps and air probes, Humidity probes, Vacuum gauges, Air velocity probes
- Before use
- TITAN/P51 provide pressure ports and absolute vacuum; separate YJACK probes provide temperature and humidity. YJMano provides differential pressure and YJFLOW current air velocity and temperature. Physical reading comparisons remain pending.
-
NAVAC
Wireless instruments
- Models
- NSP1 · NST1 / NST2 / NST3 / NSTL · NSH1 · NMGD1 · NX1 / NX1G · NX4 / NX4G · NSM1 · NMV1S · NRS2A
- Covers
- Digital manifolds, Pressure probes, Temperature clamps and air probes, Humidity probes, Vacuum gauges, Refrigerant scales
- Before use
- Available measurements vary by model. NRS2A signed tared weight and battery and NSH1 humidity are implemented from OEM protocol evidence; physical comparison is pending. Pump and valve controls are not available. NSP1 packets have been captured from hardware. NMA1 combustion acquisition is separate and is not included.
-
Refco
REFMESH
- Models
- REFVAC-RC / RC-F · REFMATE-2 / 4 · REFCLAMP · REFSCALE-S / C
- Covers
- Digital manifolds, Pressure probes, Temperature clamps and air probes, Humidity probes, Vacuum gauges, Refrigerant scales
- Before use
- Scale readings support signed tare in kg, lb and oz, including the decimal-pound wire value used by the lb-and-oz display. Attached-unit reports are accepted. The older TAP family uses a different protocol and is not covered. Physical reading comparisons remain pending.
-
JB Industries
Wireless probes
- Models
- DM4 · JB-Pres · JB-Temp · JB-Hygro · JB-Mano
- Covers
- Digital manifolds, Pressure probes, Temperature clamps and air probes, Humidity probes
- Before use
- The ambiguous JB-Vac frame is not presented as a vacuum measurement. Battery icon levels are not converted into an estimated percentage.
-
Parker Sporlan
SMART Gen 1
- Models
- Sporlan SMART Gen 1
- Covers
- Pressure probes, Temperature clamps and air probes
- Before use
- Separate connections for the original kit probes. Physical reading comparisons remain pending.
-
CPS
ABM-200
- Models
- ABM-200
- Covers
- Pressure probes, Temperature clamps and air probes, Humidity probes, Air velocity probes
- Before use
- Atmospheric pressure, air temperature, humidity and velocity. Does not calculate airflow from an assumed duct size. Physical reading comparisons remain pending.
-
CPS
BMD200 / BTM200
- Models
- BMD200 · BTM200
- Covers
- Digital manifolds, Pressure probes, Temperature clamps and air probes, Humidity probes
- Before use
- BMD200 gauge pressure and line temperatures, plus BTM200 clamp temperature and humidity. Battery is available on established status frames. Implemented from application protocol evidence; physical reading comparisons remain pending.
Instrument types
By what it measures
Find the measurement you need, then check which models and modes provide it. Compatibility and physical validation vary by instrument and firmware.
-
Digital manifolds
Low- and high-side readings on supported models.
Sauermann · Fieldpiece · Testo · Yellow Jacket · NAVAC · Refco · JB Industries · CPS
-
Pressure probes
Refrigerant, static or atmospheric pressure, with the correct reference.
Sauermann · Parker · Fieldpiece · Testo · Parker Sporlan · Yellow Jacket · NAVAC · Refco · JB Industries · CPS
-
Temperature clamps and air probes
Line, air and surface temperature.
Sauermann · AccuTools · Parker · Fieldpiece · Testo · Parker Sporlan · Yellow Jacket · NAVAC · Refco · JB Industries · CPS
-
Humidity probes
Relative humidity for air-side checks.
Sauermann · Parker · Fieldpiece · Testo · Yellow Jacket · NAVAC · Refco · JB Industries · CPS
-
Vacuum gauges
Evacuation readings on an absolute reference.
Sauermann · AccuTools · Fieldpiece · Testo · Yellow Jacket · NAVAC · Refco
-
Airflow instruments
Air volume reported by supported instrument modes.
Testo
-
Air velocity probes
Air speed; duct area is still needed to determine airflow.
Sauermann · Testo · Yellow Jacket · CPS
-
Refrigerant scales
Weight readings in supported instrument formats.
Sauermann · Yellow Jacket · CPS · Fieldpiece · Testo · NAVAC · Refco
-
Electrical meters
Distinct AC/DC, power and other electrical quantities on supported meter modes.
Parker · CPS · Fieldpiece · Testo
One set of names
What arrives on the screen
A mixed-brand truck still produces one coherent read. Every pressure carries its own reference with it — gauge, absolute or differential — so a duct reading in pascals and a low-side reading in PSIG stay the different kinds of number they are.
- Pressure
- Refrigerant, static and atmospheric pressure, preserving gauge, differential or absolute reference.
- Temperature
- Line, air and surface temperatures.
- Humidity
- Relative humidity.
- Vacuum
- Evacuation on an absolute reference.
- Air movement
- Instrument-reported airflow and air velocity, kept as separate measurements.
- Weight
- Refrigerant scale readings in supported units.
- Electrical
- Distinct AC/DC, power, frequency, resistance and capacitance quantities, depending on the meter and mode.
Pairing
Find your supported tools in one scan
The app runs a single Bluetooth scan and works out what answered. Instruments it recognises come back named by brand and ready to connect. Everything else the radio heard is listed underneath as what it is — other Bluetooth devices, no connect button — instead of being silently dropped. If your gauge is awake and still not in the top list, you can see that for yourself rather than wondering whether the scan missed it.
Once a meter is connected you say what it is reading — this probe is suction pressure, that clamp is the liquid line — so a number arrives already knowing what it is a reading of.
Get the app
Bluetooth pairing needs the installed app. It is free, and it does not ask you to sign in.
- Needs the installed app Bluetooth is a native radio. The brands appear on a phone or tablet with the app installed, not in a desktop browser.
- Where the number came from Every value records whether it was keyed in or streamed, and from which instrument.
- Only readings fit to grade get graded A probe that is not fit to grade from still streams for reference, and the screen says so — your evidence stays clean.
Compatibility research
Not available yet
These families still need protocol work, app integration or physical validation. They are not selectable in the app, and listing them here is not a release commitment.
Seeing your brand here is a good reason to send a tool request — it is how the order gets decided.
- Sauermann analyzers Combustion measurement integration and calculated hood airflow remain under review
Ask for your tool
The intake is the app’s own feedback form: Settings → Feedback → Tool request, with fields for the brand and model. It queues if you are out of signal and sends when you are back, and it lands with the people who write the drivers.
Send the exact model and firmware. That is what turns a request into an integration.
Not installed yet? Email works too.
Pair a probe, then keep the reading